Prices  NG-C5HF--  Hengesbach  Turkey

BRAND Hengesbach
Product NG-C5HF--
Description turbidity sensor
Internal code IMP4885014
Weight 1.5
Custom code 90268020
Technical specification A-TURBIMESS for high turbidity of 50... >10,000 NTU Ordering details Process connection: Clamp in accordance with DIN 32676, DN 50 --- Measurement principle: infrared stray light measurement, for high turbidity Two-wire version, with additional switching points (max. 50mA). support points in any order through integrated display and Adjustable controls. Ambient temperature: -20... +75°C; media temperatures: -20... +125°C, max. 1 hour: 150°C Material: case wkst. 1.4301; measurement window: sapphire glass; seal: silicone rubber (FDA compliant) Electrical connection: M12x1 circular connector, 5-pin Supply voltage 24... 30V DC 1x signal output 4... 20mA, 2-wire 2x PNP switching output, supply voltage, max. 50mA

default.send_request_amp_Group2