BRAND | JOVYATLAS |
Product | JOVYCUBE Ocean 20kVA - UPS cabinet |
Internal code | IMP5131121 |
Weight | 1070 |
Technical specification | <p>For Supply of Sensitive Consumers in Continuous Operation<br>On board of sea going vessels<br>Online UPS, class VFI -SS-111 in accordance with EN 62040-3<br>Standards: EN 62040-1, -2, -3; VDE 0558-530, rules of DNV/GL<br>Modular expandable UPS up to 60kVA/60kW<br>Maximum installable modules:<br>2 power modules 20 kVA/20 kW</p><p>It is recommended to equip the system with 2 power modules 20 kVA<br>/20 kW for redundancy!<br>(Will be offered separately)<br>The unit consists of two separable cabinets equipped with:<br>Input terminals for feeding L1, L2, L3, PE<br>Input transformer for voltage adaptation<br>Bypass terminals for feeding L1, L2, PE<br>Bypass transformer for voltage adaptation<br>IGBT - rectifier for sine wave input and active power factor correction<br>(integrated in power module)<br>IGBT - inverter in PWM technology with sine wave output (integrated in power<br>modules)<br>Manual bypass switch for maintenance<br>Distribution for Consumers via Automatic Circuit Breakers<br>Output terminals for consumers each L1, L2, PE<br>Touch display panel (mounted in the door)</p><p>Relay card with potential free change over contacts<br>The available messages are as follows:<br>Major alarm<br>Minor alarm<br>AC input failure<br>Battery alarm<br>Battery in Discharge<br>System Saturated<br>Module failure<br>MBCB/SBP engaged<br>These alarm messages are adjustable!<br>Halogen-free cabling (JOVYATLAS uses its own range of cable types)<br>Removable lifting lugs<br>The system is equipped with a 7" color touch display panel for<br>Menu-driven graphical display of all status data and parameters of the<br>UPS with the following features:<br>- LED for:<br>- Major alert<br>- Minor alarm<br>- System okay<br>Interfaces:<br>- USB interface for data transfer<br>- Ethernet interface<br>- Reset button<br>Bloc diagram on touch panel as follows:<br>- Indication for:<br>- AC - green LED input okay<br>- AC - LED input to network mains failure<br>- Green battery LED okay - charging<br>- Orange battery LED okay - discharging<br>- Red LED battery - battery failure<br>UPS modules:<br>Three kinds of status can be shown:<br>AC - IN<br>AC - OUT<br>BATTERY</p><p>AC output:<br>- Green LED - inverter feed load<br>- Orange LED - load > 75%<br>- Red LED - Inverter not feed load<br>LED for manual bypass active<br>Touch display panel is able to show the following values<br>Input values:<br>- Input voltage phase to neutral<br>- Input current phase to neutral<br>- Input frequency<br>- Input power<br>- Load AC - input failure<br>Battery information:<br>- Temperature<br>- Voltage<br>- Current<br>- Report of last test, last boost, last discharging<br>Select of modules, each module has its own address<br>And can be selected for checking.<br>Indications for modules:<br>- Address is green, then the module works perfectly<br>- Address is orange, then the module has a malfunction,<br>Which can be easily fixed<br>- Address is red, defective module which must be exchanged<br>- Address is grey, module has been switched off manually<br>- Address is white, free slot for additional modules<br>A click on identify button will show the values of a single<br>Modules like:<br>- AC - input for each single module<br>- DC - input for each single module<br>- AC - output for each single module<br>Description of the colors of the LED's:<br>- green à okay<br>- Orange for fixable failure<br>- Red à not fixable failure<br>Click again on select module to get back to the main menu<br>Display of the output values entire system:<br>- Output voltage phase to neutral</p><p>- Output current<br>- Output frequency<br>- active power<br>- apparent power<br>Display of events:<br>- Red major alarm LED<br>- LED with orange minor alarm<br>- LED with white information alarm<br>Click on log will show the event history for example:</p><p>Specification<br>Offered output power: 20 kVA/20 kW<br>to supply 20 kW > 12 kW<br>With Parallel Redundancy<br>Output power per module: 20 kVA/20 kW<br>Number of modules offered:</p><p>No. of max. installable modules: 2<br>Maximum installable power: 40 kVA/40kW<br>Output voltage: 1 x 230 V<br>Output voltage stability: static ± 1%<br>Dynamic 0%-100% -0%: ± 3%<br>Total harmonic distortion: linear load < ± 2%<br>: non-linear load <± 4% (EN62040 -2 -2001)<br>Output frequency: 50 Hz<br>Output frequency tolerance: ± 0.1%<br>Overload capacity: 110% continuous<br>Supply voltage UPS: 3 x 400 V<br>Input voltage range UPS: 3 x 360 V - 3 x 440 V<br>Supply voltage power module: 3 x 400/230 V via input transformer<br>Input Frequency: 57Hz - 63Hz<br>Input power factor: 0.99 of 25% - 100% load<br>Crest factor: 2.7:1<br>Efficiency:<br>100% load: AC-AC: 96%, DC-AC: 97%<br>75% load: AC-AC: 96%, DC-AC: 97%<br>50% load: AC-AC: 95%, DC-AC: 95%<br>Operating temperature range: 0 - 45°C<br>Humidity: max. 95% non-condensing<br>Dimensions and weights:<br>Cabinet manufacturer: Rittal<br>Cabinet type: type VX25<br>Peinture: RAL 7035<br>Protection degree: IP 21<br>Cooling: active cooling via fans<br>UPS cabinet dimensions: W x H x D: 2x606 mm x 2200 mm (2000 mm +</p><p>100 mm socket + 100 mm mounting angle) x 606 mm</p><p>Terminals: copper bars for power cables<br>: Terminal type Weidmüller (or comparable) for<br>Control Cables<br>Cable entry: from bottom<br></p> |
default.send_request_amp_Group2