BRAND | Hurner Funken |
Product | 368-361-000001 |
Description | HF - Direct Drive Centrifugal Fan |
Internal code | OZH4258003 |
Technical specification | Brand: HLU Type: HF R 140-15 D (DS1) Housing material: peS Impeller Material: PPs Case Position: GR 360 Suction diameter: 140 mm Pumped medium: Air Ambient pressure: 101,325 kPa Media temperature: 20 °C Absorbent media density: 1.197 kg/m³ Volume flow: 600 m³/h Total pressure difference: 431 Pa Static pressure differential: 347 Pa Operating speed: 2800 rpm max. perl Impeller speed: 5256 rpm pergil. Media temperature range: 0/60 °C Control type (on site)፦ Operating frequency: 50 Hz Inlet velocity: 11.8 m/s circumferential speed: 32 m/s Sound pressure level Lp2A (1 m): 59 dB (A) Sound pressure level Lp2A (1 m) *: 62 dB (A) Sound power level Lw6A: 71 dB (A) Impeller Efficiency: 75.9% SFP: 885 [3] W/ (m³/s) Power requirement for shaft: 0,094 kW Engine power: 0.25 KW Voltage: 460 V Frequency: 60 Hz Rated current: 0.63 A (400 V) Design: IM B5/63A Protection type/motor protection: IP 55/PTC Speed: 3465 rpm Ex classification፦ Motor suitable for FU: Yes Addition: Engine brand: Siemens, engine acc. to UL |
Press on flag images to see contact information!