BRAND | Kem Kuppers |
Product | ECO-K1-PN-AP-Ex |
Description | ECO - Modular pulse amplifier |
Internal code | OZH4835891 |
Technical specification | for easy flow detection ECO Frequency range: 1 to 5,000 Hz Supply voltage:12 to 27 V/DC K Assembly: screwed, M14x1.5 for ≤ ZHM 04, HM & SRZ Medium temperature: -40°C to +120°C 1 Channels: 1x flow P output stage: active, push-pull, NPN, PNP N extended output function: none A Housing material: die-cast aluminum Protection class: IP65 P Electr. Connection: M12x1, plug 5-pin, A-coded Ex: Product Certification Code T200 ATEX: II 1G Ex ia IIC T4 Ga IECEx: EXia IIC T4 Ga UKCA: II 1G Ex ia IIC T4 Ga CSA: Exia IIC T4 Class 1, Division 1, Groups A, B C, D, T4 Class 1 Zone 0 AEx ia IIC T4 Ambient temperature: -40°C ≤ Tamb ≤+60°C -40°C ≤ Tamb ≤+50°C Install via T100_D_EN_230130_E*** * replacement for VTER/P-ex-05 |